NIME1116-DIDEER-A | ||
The EtherCAT IO module product adopts a fully isolated design solution, which has good product stability and strong anti-interference ability. |
||
Functional Features | ||
·EtherCAT bus, modular distributed slave station, 8 bidirectional optocoupler inputs, 8 relay outputs |
||
Compared with similar competitive products | ||
The modular design and EtherCAT bus communication network make NIME1 remote I / O easy to use, smart, and strong anti-interference performance, which has obvious advantages in distributed control. |
||
Application cases & scenarios | ||
Suitable for industrial gantry, CNC machine tools, industrial printing presses, industrial robots and other industrial automation equipment applications |
||
Digital input | Digital output | |
·Number of channels: 8 ·Input Type: Bidirectional Optocoupler (NPN / PNP) ·Filtering time: 0.5ms ·Rated level: 24VDC (-15% / + 20%) ·Port protection:- ·Isolation withstand voltage: 3750Vrms (MIN) |
·Number of channels: 8 ·Output type: relay ·Rated level: 30VDC / 250VAC ·"1" signal level: relay dry contact is closed ·"0" signal level: relay dry contact is disconnected ·Maximum output current (single channel): 1.0A ·Maximum inrush current (single channel): 2.0A ·Maximum total output current: 8.0A ·Port protection:- ·Isolation withstand voltage: 3750Vrms (MIN) |
|
Physical properties | ||
·Power supply voltage: 24VDC (-15% / + 20%) ·Communication protocol: EtherCAT ·Communication speed: 100Mbps ·Address configuration: automatic scanning ·Product size: 103 * 103 * 46.7 (WDH) ·Installation method: DIN rail installation |
||
Interface Description | ||
Signal | Name | Description |
Features | ||
Power supply |
+24V | Power input, connect to DC power 24V |
0V | Power input, connect to DC power ground | |
PE | Shell ground | |
Input port |
DI1 - DI8 | 8 input signal channels
The signal is valid, corresponding to the input indicator.
|
COM | Input signal common. 1.COM ground, the input signal is active high
2.COM is connected to 24V, the input signal is active low
|
|
Output port | D01 - D08 | Output signal, relay dry contact. Group D0 is the two output nodes of a relay, and so on. The relay dry contact is closed, the output is valid, and the corresponding output indicator is on. |
Principles | ||
1.Digital input equivalent schematic In the figure above, M is the common terminal of the external input signal, and IN is the external input signal. Note: The maximum drive current of the output signal is 1A. Please check the rated power and internal resistance of the external load before use. If the load requires more than 1A, please increase the current limiting measures as appropriate. |
NIME1116-DIN-A | ||
The EtherCAT IO module product adopts a fully isolated design solution, which has good product stability and strong anti-interference ability. |
||
Functional Features | ||
·EtherCAT bus, modular distributed slaves, 16 sink inputs (NPN) |
||
Compared with similar competitive products | ||
The modular design and EtherCAT bus communication network make NIME1 remote I / O easy to use, smart, and strong anti-interference performance, which has obvious advantages in distributed control. |
||
Application cases & scenarios | ||
Suitable for industrial gantry, CNC machine tools, industrial printing presses, industrial robots and other industrial automation equipment applications |
||
Digital input | Physical properties | |
·Number of channels: 16 ·Input type: NPN ·Filtering time: 0.5ms ·Rated level: 24VDC (-15% / + 20%) ·Port protection: Overvoltage protection ·Isolation withstand voltage: 3750Vrms (MIN) |
·Power supply voltage: 24VDC (-15% / + 20%) ·Communication protocol: EtherCAT ·Communication speed: 100Mbps ·Address configuration: automatic scanning ·Product size: 35 * 105 * 116 (WDH) ·Installation method: DIN rail installation |
|
Interface Description | ||
Signal | Name | Description |
Features | ||
Power |
D24V+ | Power input, connect to DC power 24V |
D24V- | Power input, connect to DC power ground | |
PG | Shell ground | |
Input port |
DI1 - DI16 | 16 input signal channels, active low.
The signal is valid and the corresponding input indicator is on.
|
24V | The input signal power is 24V, which is internally shorted to D24V +, and the external can be used as the sensor power supply. |
|
Output port | 0V | Input signal power ground, shorted internally with D24V-, external can be used as sensor power supply. |
Principles | ||
1.Digital input equivalent schematic In the figure above, IN is the external input signal, 24V is the positive pole of the power supply for the sensor, and 0V is the negative pole of the power supply for the sensor.
Note: Each channel of the input signal power supply can provide an output current of 500mA. Please check the rated power and internal resistance of the external sensor before use.
|
NIME1116-DOER-A | ||
The EtherCAT IO module product adopts a fully isolated design solution, which has good product stability and strong anti-interference ability. |
||
Functional Features | ||
·EtherCAT bus, modular distributed slave station, 16 relay outputs |
||
Compared with similar competitive products | ||
The modular design and EtherCAT bus communication network make NIME1 remote I / O easy to use, smart, and strong anti-interference performance, which has obvious advantages in distributed control. |
||
Application cases & scenarios | ||
Suitable for industrial gantry, CNC machine tools, industrial printing presses, industrial robots and other industrial automation equipment applications |
||
Digital output | Physical properties | |
·Number of channels: 16 ·Output type: relay ·Rated level: 30VDC / 250VAC ·"1" signal level: relay dry contact is closed · "0" signal level: relay dry contact is disconnected ·Maximum output current (single channel): 1.0A ·Maximum inrush current (single channel): 2.0A ·Maximum total output current: 16.0A ·Port protection:- ·Isolation withstand voltage: 3750Vrms (MIN) |
·Power supply voltage: 24VDC (-15% / + 20%) ·Communication protocol: EtherCAT ·Communication speed: 100Mbps ·Address configuration: automatic scanning ·Product size: 35 * 105 * 116 (WDH) ·Installation method: DIN rail installation |
|
Interface Description | ||
Signal | Name | Description |
Features | ||
Power supply |
+24V | Power input, connect to DC power 24V |
0V | Power input, connect to DC power ground | |
PE | Shell ground | |
Input port |
VCC | IO power input, connect to the positive pole of DC power. |
0V | IO power input, connect to DC power ground. | |
Output port | D01 - D08 | 16 output signal channels. The signal is valid, DO and VCC are on, and the corresponding output indicator is on. |
0V | Internally short circuit with IO power 0V. The load can be directly connected between DO and 0V. | |
Principles | ||
1.Digital input equivalent schematic In the figure above, VCC and the IO power supply are shorted internally, DO is an output signal, 0V is internally shorted to the IO power ground, and the load can be directly connected between DO and 0V. The signal is valid and the indicator light is on.
Note: The maximum drive current of the output signal is 1.0A. Please check the rated power and internal resistance of the external load before use. If the load requires more than 1.0A, please increase the current limiting measures as appropriate. |